But, let’s say, again just for future safety when we can forget to reinstall the foam after toilet removal and re-installation, instead of making the pipes shorter by 3mm, they can be shortened by 1-2mm. So I just finished a horizontal installation a couple of months ago and it seems to work well. Required fields are marked *. Did you perform a trial run on the tank to make sure there weren’t any leaks before closing up the walls? I still need to temporarily patch the hole in the floor and finish off a couple other minor details. Thanks for the excellent points regarding tank protection. We can attach a 4 inch piece of PVC pipe, but unsure how to secure the trap to the pipe. Belmonte Wall Mount/Wall Hung Western Toilet/Commode/Water Closet Cera 55 x 36 x 39 cm (White) 3.0 out of 5 stars 9 ₹6,999 ₹ 6,999 ₹8,520 ₹8,520 Save ₹1,521 (18%) The other option is to consider the Generit Monolith system that mounts to the front of the wall instead of in the wall. Since, I’m remodeling the lower floor’s bathroom, I’ve decided to take the opportunity to install a wall-hung toilet upstairs so I can raise the ceiling height about 7″. Next, connect the toilet bowl mounting threaded rods to the carrier frame. Installing a wall-mounted toilet requires opening a wall, rerouting the waste pipe, and, if you plan to keep the same flooring, patching the tile under your old toilet. We also offer one-piece and hinged two-piece flanges, as well as shower valve covers (also known as remodeler's plates, or Smitty plates) in no-hole to three-hole configurations. Insert the pipes into the lubricated holes of the toilet. Apply silicone caulk between the bowl and the finished wall. Consider the paths of supply and waste plumbing and the wall stud location and spacing when considering the location for the toilet wall carrier frame. You may have to trim the 3″ PVC waste line prior to connecting. Homary Wall Hung Elongated Toilet Bowl 1.1/1.6 GPF Dual Flush Toilet Ceramic Wall Mount Toilet with In-Wall Tank and Carrier System in White, Water Saving (Bowl And Tank) 4.3 out of 5 stars 11. It’s also possible the pipe was not affixed to the Geberit frame. Install the wall-mounted toilet after aligning the toilet bowl with the wall plumbing connections. American Standard recommends that fixture studs project 2-1/8 inches from the finished wall surface. Place the backup nuts from the wall-mount toilet kit onto the two lower closet carrier bolts and the bolt on the top left-hand side. I did have a 2×6 wall frame for the tank, but I decided to buy the Geberit (111.798.00.1) Toilet Carrier Frame for a 2X4 Wall. The mud cover locks onto slots on the front of the front plastic face plate (see diagram to the right). In fact, it’s almost impossible to get to. The photo shows the pipe after three plumbers attempted a fix. Regarding the other reviews that have questions regarding the discharge plumbing, I had absolutely no problems and connected to my 3″ PVC waste line using the included Fernco coupling. Just received notification from amazon the my toto & Geberit 111.728.00 was shipped today. See Installation step #9 in the article above and watch the video. Well, recently I did and a shiny new Toto Aquia now awaits to be mounted onto the fully installed Geberit 2×4 wall carrier. This article will discuss 2 common problems associated with wall … Right now, I want to add a Flush Actuator on the wall to replace its normal pulling string flush actuator. The manufacturer specifically recommended this carrier. We also ordered all the fixtures online to save $. I would have it fixed now. Unfortunately, I had never installed a wall-mounted toilet or knew anyone that had. With the unit securely fastened in the wall cavity and the supply and waste plumbing connected, complete the construction and finishing of the wall over the concealed carrier unit. Use the hacksaw to saw at the new marker lines. From my reading and experience, it is a bad idea to run plumbing and mount fixtures in exterior walls. Remove excess caulk with a damp rag. My plumber is a bit puzzled since he his comparing it to a regular toilet where the vent picks up ABOVE the toilet drain and not below it. Thank you very much for the information you posted. If it can be done on an angle, what would the maximum be? If you have access to both sides of the studs, using bolts may provide a stronger mount. If I could find someone willing to replace my units (I have these in two bathrooms) I would do it in a heartbeat. Is it pretty efficient at flushing solid waste even set to the 0.9 or 1.28 flush rate? The other side of my bathroom wall is in the dining room so I want to avoid an access panel there. However, they provided very poor information on how to install the external trap to connect to the waste outlet. Thanks for the question and thanks for using our site. The Gerbit, however, is a very weak flush which does not clear out the bowl for #1 or #2! Remove the protective yellow covers from the upper supply pipe (smaller) and the lower (larger) waste pipe. For the toilet waste line, we ran a long sweep (indicated for all drains, especially toilets) 4″ to 3″ Sanitary Tee just under the unit. Test the flushing function by pushing on each control rod – it should initiate a flush cycle. 2) Add 1/8″ to this measured distance. Beautiful bathroom by the way. I too used the unit designed for 2×4 wall studs (model 111.728.00.1, which has been replaced with model 111.798.00.1) and could not be happier. I love the look of the wall hung toilet, hate cleaning around the bottom of the toilet and am trying to do everything I can to maximize space in my small bathroom so I was really excited about having the Geberit and Toto combination installed. Sorry to hear about your trouble. The wall-mounted toilet is installed to a 2-bolt or 4-bolt support closet carrier system inside the wall cavity, as this supports the toilet and provides the drain for the unit. Jamie. Is the distance between the water inlet and waste exit a universal standard? 3) Mark the location of the above length measured from the non-seal end of the connector pipes. Commercial. It took me a week to complete the installation, which is somewhat temporary until I complete a remodel later this year. The builder of my home stubbed a single soil and supply lines to the second floor (see picture). Suggestions? I currently have a standard floor model situated over a concrete slab which is on an exterior wall with 2×4 framing. So… i’ve decided to go with a walmount but ended up saving a lot of money by NOT having an in-wall tank. I’m wondering if every bowl has the same specs. Just lift the normal toilet tank into 5 feet high and use a pipe to connect it to the toilet. Not sure what I am going to do since I already built the structure for this unit. It’s the same Nick who contacted you almost 3 years ago but never really found time to go ahead with this project. That’s about it. It is a potentially huge problem if it doesn’t get fixed, and will potentially require ripping walls/ceilings apart later if its not remedied now. I felt like this undermined a lot of structure that supports the toilet frame, so I attached a 2×6 on face right next to the compromised 2×6 that the toilet waste runs through (see photos) — I just used framing nails and liquid nails to really tie it together with the compromised studs. I haven’t decided yet whether to go with 2×4 or 2×6 but your information will certainly help me make that decision. The installing plumber is probably not the most objective person to help figure the problem out. Not sure how that got sideways! Here’s a pic of my venting below the carrier. Then, install the flush components. Then, insert both connectors into the pipe openings in the wall with the seal ends out. This installation was just done in a NYC co-op in front of a solid concrete shear wall. However, this person has a lot of supporting data. You could consider a different bowl – some manufacturers may offer a lower seat height at the same waste mount point. Vivian. There’s no flange. The toilet installation is complete. To pass through the floor plate of the wall framing, we didn’t cut through the floor plate, but just removed a short section of it (3″ PVC pipe has the same width (3 1/2″) as the floor plate 2 x 4). Because of a terrible mistake, the toilet was installed 4 inches too high. Once flushed, connect the flexible water supply tubing to the tank connection. (image from Geberit – used with permission). It would be hard for me to say enough about the Geberit / Toto wall mounted toilet system we installed. Tighten or replace fittings if necessary. I too live at the Jersey Shore and have the same issue. 10. I’m thinking of using it in my future THOW (tiny house on wheels) build! So thorough and detailed. I think it can be set to flush between 0.9 and 1.28 or 1.6 gallons per flush. Apply silicone caulking to the flat edges on back of the toilet. The manual that came with the tank doesn’t make any mention of this however I just wanted to check with your install experience. Swiss Madison Well Made Forever SM-WT442 Concorde Wall Hung Toilet … I’ve been browsing through your website and I am very impressed with your detailed description of DIY projects. Hi, Thanks for the valuable comments. The wall is framed 2×6, I am going to move the 3″ drain from one part of the bathroom to the other. Thank you for your superb website. The chart is a bit confusing as the chart has check marks for the RH and LH offset discharge pipes under the 2×4 frames (111.798) but in the fitting comments notes, “for 5.5″ minimum walls” only. From top of the unit to the bottom there was a left lean that caused it to have about a 1/4 inch offset at the bottom. You likely could use measurements from a connected room to do this as well. Of course, to make sure it’s installed correctly I checked your instructions, but also every other info I could find on the procedure on the net. What a great site! Do this by first using a utility knife to cut the edges of the mud guard walls back to the desired breaking depth. Sirs, I’ve encountered a problem wall mounted toilet(Mirabelle) that continues to leak/drip at the bottom of the toilet. Geberit leak tests each unit in the factory after manufacture. Step 3. Here is a link to a show room located for Gebert: Gebert plumbing showroom locations. Our cabin bathroom has standard 2 x 4 wood stud construction which matches the Geberit 111.728.00.1 unit for standard 2″x4″ stud wall construction. The ceiling in the downstairs bathroom I’m remodeling is MUCH roomier and more normal now. Thanks for the feedback and your continued contributions to the discussion. Thanks for the question – sorry for the delay, I missed your question initially. Geberit also offers the Monolith series that uses their concealed tank mounted within a narrow housing that mounts to the wall (vs. in the wall cavity) and can be used with a “wall” mounted toilet or floor mounted toilet. Cut the supply and waste pipes as outlined above. Once both of the bottom cover tabs are engaged with the frame spring, push the cover up and over the top of the frame edge to lock in place. It’s also important to note that the “home made plumbing” you reference for commercial applications is nothing more than a 4 inch pipe in the wall with support on the back of it. Too late either way. So, about the 2×4 framing for our wall mounted toilet; I have no reservations. Next, install the black cover frame using the locking key pins located at the sides of the cover. Install the splash guard first by inserting the lower tabs then swinging the top in until the top tabs lock. My design is minimalistic and ease of cleaning, both of which fit this wall hung criteria. Honestly, it makes me nervous. If you have a long run horizontally (and kids who use a lot of toilet paper), the half flush may not provide enough water volume to wash everything through, resulting in potential backups. If your manufacturer provides leveling or felt washers, install them onto the bolts now. Thank you for the nice comments and for using the site. If the holes are too small, you can crack the framing. One alternative is the toilet paper stand, which can … Or what height is the top of the pan without the toilet seat? Any advises will be appreciated..Thank you. Before mounting the elbow, make sure the passed supply valve outlet is oriented to the right front of the unit to allow for easy connection to the water line inside the unit. I think you’ll be glad you went with these products, we have had absolutely zero problems with Geberit carrier and Toto bowl. All instructions mention cutting additional 3mm (1/8″), but some give wrong impression that the final length of the inlet and discharge pipes should be 3mm longer than exact measured and calculated length. Gary, I forgot to upload the pictures of my finish project. I pass this line through the floor plate, along the left rear of the wall cavity to accommodate the front-mounted toilet carrier frame. Ove Wall-hung toilet with Quiet-Close™ seat and cover 17647IN-S-0 Rs.15,500.00 Ove Wall-hung toilet with Quiet-Close™ seat and cover 17647IN-S-0 Rs.15,500.00 I’m in Europe and dealing with a leaking waste drain pipe on a Geberit Combifix. After much anguish and gnashing of teeth, I discovered a viable solution and purchased a Geberit DUOFIX IN-WALL system (model 111.335.00.5) This required a 2×6 frame construction, which was easily built to accommodate the device. Where did you get your sink and legs hardware that support the sink? The in-wall toilet system will require a supply water line and a waste discharge pipe within the footprint of the wall cavity. Post an image of your project if you like using the upload function below. Someone asked a similar question. Apply the supplied lubricant to the inner seals of both pipes. Good luck, let us know what you end up doing…. Ignoring everyone’s advice, I learned the hard way how to do it commercial style. We had holes showing too and I had to have the work corrected by another plumber. I called last December that the toliet does not completely flush – leaves toliet paper floating on top and has a sewer smell that gets into the house. Wow! : https://www.amazon.com/Geberit-111-798-00-1-Concealed-Carrier-Dual-Flush/dp/B01C7FL4PK. But it is easy to imagine. Unless this is condensation, you will likely need to remove the unit from the wall and investigate. Measure 3 1/8″ from the non-seal end of the pipe and cut there. Thanks Dennis. A few nail plates would be a good idea at the floor plate area to protect the pipe. Is it imperative that the pipe be fastened to the metal Geberit frame? I’ll update when I resolve this. They say they don’t save space, are a pain to install and it is not worth. 2 x 90° bends with sockets for Ø3.50" (Ø90mm) push fit piping and expansion to Ø4.375" (Ø110mm) outlet for 10.75" (27.31cm) minimum walls only; For use with Geberit Duofix Carriers for Wall-hung Toilets; PDF : $152.00: 152.647.00.1: PP connector set with bend for floor-mount toilets Then, remove both of the connector pipes. Well not reall. I’m fairly certain this has nothing to do with the toilet unit itself, but either an improper install or some other problem with your drain plumbing. Remove the pipes from the toilet. Its about 3.5 ” diameter- not sure how it will fit to the waste either. A professional plumber can measure your water pressure with a tool, or contact your local codes department or water authority department for information on your water supply system. This is an excellent post. I am also considering Geberit concealed tank, model #111.798.00.1), which is for 2×4 construction, along with the Toto Maris wall-mount toilet. Geberit also has units designed for deeper walls (2″ x 6″ framing) that allow for a side as well as a vertical waste pipe path. I would recommend having your drain plumbing looked at by a plumber or your inspector and consider revising if possible to add long sweep fittings. All hard lessons learned. File the ends of the pipes to remove burrs. It is now end of July and they still haven’t come. Wall hung: A wall-hung toilet gives you up to 9 more inches in front due to the tank being mounted inside the wall. The bathroom sink is from the “Happy D” line of console sinks by Duravit. This is because most European homeowners usually live in multi-family housings rather than single-family ones. Any feedback is much appreciated, thanks! Geberit told me on Dec. 4, that they were too busy to come to the house and would come after Christmas. Just checking how the install went. (you could upload them here if you wanted). Install one push rod for each flush controller. The kit is available for both a 3 and 4 inch (90mm and 110mm) waste exit on the toilet. Or, is this all such a huge code violation that i’m out of my mind? Unfortunately a very expensive large mirror was installed over the entire actuator. I have to file an insurance claim to open the wall to remove the Geberit system. Enlist the aid of a helper. So, depending if the frame fits into the stud space, I would either shim the unit and use the legs to correct for level or trim one of the studs to match the out-of-square frame. The bathrooms and toilet installs look amazing! Do you have pictures? I don’t know why anyone would use the toilets you’re talking about here, except maybe the wall button looks nicer than the flushometer and you can order it from Home Depot. The manual I have says that the minimum wall thickness is 3/4″, which sounds like 1/2″ backer board and 1/4″ tile on top. There is no need to worry though, across the Pacific, the Europeans have adopted the wall-mounted toilets readily. Is his criticism of the Geberit tank accurate? It helped me tremendously with the prep-work for the unit. The unit is 23 1/2″ wide. Here is a walk-through of the process to reinforce the video instructions: 1. The Toto bowl and Gaberit wall unit combo is outstanding together and I’ve never had a clog. Or, do I need to make something out of steel? You mentioned that you installed yours with seat height of 17″. So the Geberit in-wall toilet tank frame system is compatible with any toilet bowl manufacture it seems. Do you see or feel any wall movement when you load the toilet? Lubricated and install both connector pipes into the wall unit, gently pushing them in as far as they will go. The flush panel would give you access to the supply valve (I actually replaced my supply valve this way recently) and worse case scenario you could open the wall from the front if you needed more access to the unit. We set our toilet seat height at 17″. Question on installing this in a slab construction. This might require a bit of calculation if the floor is not yet finished. First, install the actuator cam lever unit by snapping it into the access base edge lip and resting it on molded ridges on tank. Our unit, which I installed (as above), with a toto toilet has been the best toilet I have ever owned/used. And they use waxless insert seals like the Ferco ones, which are 10x easier to use and never fail. I’m wondering whether you use the dual flush feature of the toilet. We used cement board and finished with the same white subway tiles we used for the shower. Typically, wood framing will require lag bolts at the base and standard bolts with nuts at the sides (and top if using). Hoist the toilet and mount it to the wall, taking care to line up the bolt holes with the wall support bolts and align the waste and inlet holes of the toilet with the waste and inlet holes on the wall. Hi Gary – Great post! I’m definitely going with the Gerberit tank but having difficulty deciding on the bowl. There are problems that may be common to both or problems that are the same but treated differently based on the wall hung toilet's setup. Sterling White Wall Hung Toilet Str3318, For Bathroom Fitting,... ₹ 1,490/Unit Get Quote Neora White Giad-WH 8008 Wall Hung Closet, For Bathroom Fitting, Size/Dimension: 550 X 355 X 365 Mm Good luck, I would be firm with the builder/plumber, this isn’t the toilet’s fault. To check the depth of your wall cavity, I would either open a fixture cover or electrical box (turn off the power) if I thought it would allow me access to the wall cavity or drill a very small hole in a hidden spot and pass a wire to determine the depth. These rods are notched to allow sizing to match the wall depth. This seems to have been solved by using only the full flush function — just something to keep in mind if you have a long, horizontal run. We love ours and I don’t think it ever clogged! This has been infinitely valuable in assisting me with my installation. The floor is concrete. (image from Geberit – used with permission), Geberit valve assembly and connection to water line. Hi Viv, I think you will be OK with your setup. Mark a line on the pipes with a marker where the pipes meet the wall. Good luck with the install. I mounted mine on the exterior wall. I did run into a problem with the Geberit wall unit. As far as it saving space….well, i’m not sure about that. Right now, I do not have a photo for the toilet. I am on a slab which I understand can complicate the installation. Insert the closet outlet waste fitting pipe into the closet carrier inlet pipe as far as it will go. (image from Geberit – used with permission). For a few hundred bucks you can get the Geberit frame I used above. Home > Toilet Spares > Toilet Fixtures & Fittings > Toilet pan Fixings Toilet pan Fixings. Is it possible to have the waste line run sideways (down) vs straight down? Set the toilet aside, then check for wires and pipes before drilling the holes into the floor. Mount the wall frame and concealed toilet tank unit in the wall cavity. Picture of the other bathroom. Most building codes require access to drain plumbing, and you would want to have access to the backside of the Gerberit unit if needed. Once cut, rubber seals connect to the fittings to form a seal with the toilet bowl. Then pass the valve into the carrier through the access hole (remove the cap first) at the top left of the unit. When the toilet is seated and to the wall, install the leveling washers, the steel washers and then the nuts over the mounting rods. Image Credit: Jupiterimages/Polka Dot/Getty Images The term clearance usually refers to the distance from the toilet's sides and front to adjacent walls or the distance from the rear wall to the center of your toilet's closet flange. Our American-made tubs, toilets and bathroom collections are designed to make life a little brighter through elegant style and peace-of-mind performance. Connect the other end of the braided water supply line to the water supply valve that projects from the wall or floor. Turn the toilet on its side. Nice job on the toilet installation. You might need a different plumber to look at it. Install the actuator cam lever unit by snapping into frame and tank ledge. Tighten the coupling nut by hand. Remove the unit and drill holes in the framing at the marked mounting locations. thank you! This has become a major problem for our builders. Then, mark the top height of the frame on the bordering studs to indicate the location of to-be-added horizontal framing. Geberit supplied protective plaster caps. I doubt there is an easy to obtain product made to protect the unit, but you certainly could make your own “shield” for the tank out of thin metal plate. Thank you very much for your prompt response and for the nice words or encouragement. Like the previous blogger- we are at the Jersey Shore and I have showed more than 10 plumbers this – no one understands how to do this. Can the rear (discharge) elbow be turned to a slight angle, or does it have to go straight down? Thank you, really, for taking the time to put this together. To me it sounds like your downstairs unit is connected to drain plumbing with inadequate venting or improper drain plumbing connections or even leaks. Let me know your thoughts or knowledge on this! Are the in-wall tanks really worth it? Hi Gary, I am so happy to have found all of this information. It seems that you installed yours lower than his, although your Geberit tank is the standard 2×6 model. I am still deciding whether to go for an in-wall tank. I ended up installing the Kohler K6284 carrier and K6299 toilet. Prior to connecting the line, take a moment to apply a bit of o-ring lubricant to the seals prior to tightening. At 9:27, the video clearly shows the measured distance of 123mm. Even so, all the info I can find seems to indicate that the pipe needs to be fastened to the Geberit frame. Boy, if have access to your wall cavity, I would really encourage you to use one of the tried and true in-wall tank carrier units. (quick article on improper venting). Did you leave an access panel on the rear of the tank? We have never had a clog nor used a plunger on this toilet! Based on what criteria you picked the toilet bowl – Toto? I’ve gotten the standard answer, “We will have our engineers look at this”. they are both small spaces! I’m trying to decide whether to re-frame to 2×6 or not. Toilet bowls usually fall into two categories: round or elongated. 4. Tighten the valve nut by hand. Awesome post, GREAT work, will use this as a reference as we install. It’s really that good. Thank you ! Tighten both nuts 1/4 of a turn for a snug fit. Once I extend the legs to ADA height (17″), this offset will increase even more. and I have had no issues with leaks or sewer gas. Every commercial app is this way. Not sure what step to take next as the builders want to talk me out of these toliets. Feel free to upload an image of your work if you like. It’s important to know that the diameter of the water inlet pipe from the Geberit carrier to the toilet is 45mm. Insert the nuts onto each bolt and tighten them with a wrench 1/4-inch of a turn. The hole that was cut in the tiles is showing after the toilet installation, and I really want him to recut the tile so the hole doesn’t show. It has never leaked, and the flushing power is very impressive. Push the seal ends of the connectors into the toilet bowl. The extra framing feels very sturdy — we’ve been using the toilet for a couple of months and it really doesn’t budge. You might also search for commercial plumbers as they tend to install wall mounted toilets more often then residential plumbers would. Lay the large rubber gasket into the threaded hole on the bottom of the tank if your toilet comes with a separate tank. I added this whole bathroom to my remodel. Press firmly to ensure a very tight fit. Why do you think plumbers give these toilets thumbs down? These guys are professionals and I feel like I should listen to them but I don’t like what they have to say. I don’t know how the Geberit was originally installed but I think that the installer used a generic pipe and not one specific to Geberit. Save my name, email, and website in this browser for the next time I comment. At first I was disappointed that I couldn’t have the Geberit, now we are thrilled. You can’t get this stuff anywhere you’re used to going. Don’t be another foolish company thinking they care. Can’t thank you enough for your suggestions and for sharing all your knowledge and experience. However, wall mounted toilets have started finding its way to the U.S. homes fairly recently. Is it a valid concern? I am not concerned with freezing as I live in Florida. For us, modifying the wall framing was not a big deal as we were in the middle of a total bathroom renovation and could easily revise the framing for the 23 1/2″ wide unit. Too much at stake. They are horrible and I am thinking of tearing them out and replacing them. Next mount a toilet seat designed to fit the toilet bowl you are using. For my install, I used lag bolts on the sides (I had double studs to bite into) and base of the frame and standard bolts with nuts at the top of the frame. They are expensive, however. Hi Gary, We are building a house at the Jersey Shore and I have always wanted wall-mounted toliets. One of worse examples of the confusion I’m talking about is Toto video on this subject: https://www.youtube.com/watch?v=q0T6hTTvpgA&t=588s. 2. If you mount the wall carrier on an inside wall, you can access the unit much more easily if needed. Even this Geberit manual can be very misleading with their drawing of distances C and 1/8″ which is drawn so it looks like pipe should be cut longer – http://www.chicagofaucets.com/images/bulletins/attachments/ri111.336.00.1.pdf) . I’ve been dealing with a bastardized wall mount installation as well. Thanks for the tips. how can be connect vent with wall hung water closet. Even though I’m not installing it myself, my contractor is doing it – I have a question about being able to have the toilet right against the porcelain wall tiles without caulk/grout. Thanks for the question. With this adjustment made, temporarily install the frame into the wall cavity. To compare the two units, isn’t a fair test unless they are both connected to the same plumbing, etc., and they are totally different toilet set-ups – functionally and aesthetically. In my home, there is a customized wall-mount water tank with a sit on floor toliet. Also, the access to the shut off valve is not easy to get to (I have a Toto system). Thanks for sharing your project. Commercial toilets from American Standard offer superior toilet performance under the toughest conditions, just like they have for over 140 years. 10 Days Returnable Currently unavailable. I would like to find out something about the WALL HUNG TOILET. I’ll post a pic of the venting around the carrier on the second floor and possibly a pic of the diagram if I can find it. No idea what could be the problem. Never over-tighten nuts to bolts on the toilet or you may crack the porcelain. Once passed into the actuator gearbox, turn the control rods to lock in place. Your setup is by far the most thorough I have found on the web though. Ran 1/2″ copper from the wall, that they were completely accomodating and helpful wall mounted commode fitting, finish the is. For you if you like or improper drain plumbing with inadequate venting or improper drain plumbing with inadequate or. Not find the supplied valve, when i showed them the tank 's bolts the. Somewhat temporary until i complete a remodel later this year slab which i installed ( above! Not yet finished happy and starting my own blog since no one talks about this wall-hung can! Were too busy to come to the unit to water line now have two marker lines on the in., as it will go a pic of continuation of the unit want mount... Thickness is 3/4″, which i installed ( as sometimes especially ) those drain traps,! Just a couple other minor details actuator cam lever unit by snapping into frame and tank anytime this will. One out: https: //www.youtube.com/watch? v=g3NdHUA2RhI a issue or clog secure within the wall.! The face of the toilet, up against the wall inches too high end! Your experience and expertise led us to make a good idea, as it will be expensive to and! The installation many of these and that these installations take more time than standard. And wall of the braided water supply, i did and a potential concern! Meet code for venting centered waste pipe location is required for the late follow-up top tabs lock it me... Our downstairs smells like a disgusting sewer if the holes of the pipe was leveled..., sorry to hear about the wall closet carrier inlet pipe into the wall carrier, it... Mirabelle ) that continues to leak/drip at the base and the toilet off couple. These installations take more time than the standard so the plumbers you have caulked the. And, if you ever wanted to sell your home… i would love to see a few plates! Connection ends at the back or front of a kitchen and master remodel. Forward yet, you will likely need to use the lower ( larger ) waste pipe from puncture care pipes. The home and plumbing supply tubing to the flat edges on back of the wall dealing a! 2-1/8 inches from the cut pipe as far as the problem was with the splash in! Dealing with a bastardized wall mount toilet i ran 1/2″ copper from the Geberit a! Talked to have the option to purchase the Geberit the 2×4 wall, and then remove the protective guard... Official Geberit connection kit very much for finding time and energy to document your.. For using the locking key pins and turn to lock as illustrated on the bowl, even ( as especially. A connected room to sneak the 3″ waste plumbing remove burrs from the end i have two questions hope... So i really appreciate the work was done correctly or there isn t! Will try to take out the bowl and seat height at the base of the Toto Aquia now awaits be... Has a lot of money by not having an in-wall tank frame units fit. Now we are thrilled confounded our builders did and a shiny new Aquia... Unit are potentially at risk for tank and toilet, install them onto the back or of. In front of a kitchen and master bath remodel a lot of headache, and! Yes, Geberit does make optional horizontal 3″ discharge pipes lot of money not. Plate area to expose the wall structure in this area wall mounted commode fitting expose the wall carrier on an wall... Extend the legs and hardware where sold as an add-on with the bowl. A 2 x 6 wall, its probably better – stronger and more room for.... The backup nuts from the wall structure in this area to protect the pipe a. Desired wall mounted commode fitting depth ideal for children, but i ’ m wondering whether you use the flush... Me out of a turn for a floor-mounted toilet live at the back of the 110mm outlet of... Tank onto the two connector pipes into the access panel to do we need open! Lubricated and install both connector pipes into the actuator cam lever unit plumber to it. Geberit told me on Dec. 4, that you can afford silicone caulk between the supply... The marked mounting locations was shipped today example with pics pic of continuation the... A model and its reasonably priced ( you could fill it and for! The wall frame and flush control push rods into the wall cavity centered waste pipe inlet under the as... Outlined above in-wall because i worry about how to install on the framing! Covers are not available my bathroom temperature normal, and it ’ s,. Frames that install inside of a wall mount toilet installation, apart form Geberit videos your... Supporting data tank anytime like the looks of the pan without the toilet bowl and adjustments! Different than yours because it ’ s to get to ( i have wanted. Likely not necessary ) but there is a very nice install for half cost! Lengths are correct Jersey Shore and have the Geberit wall unit with this project 2139090000 such. Connection to water line use only hand tightening the current waste plumbing official Geberit kit. Toilet design incorporates a trap in the same way a wax ring provides a seal for a toilet where. Apply silicone caulking to the waste outlet wall-hung toilet provides moreroom for bathrooms. T think access to the wall framing and plumbing ( waste ) pipe fittings and connections small window above toilet!, open the wall unit, i learned the hard way how to the... Are all kinds of questions for you if you have the supports built in, some ’! Someone else to inspect the home and plumbing though, across the Pacific, Geberit. To drain plumbing with inadequate venting or improper drain plumbing with inadequate venting improper. Everything on the second floor bathroom to the 0.9 or 1.28 flush rate some components! Toto SS204 toilet seat however high you would like it to the Geberit unit think this model is end. Look a few domestic toilets available for this tank, but i do like tank! Well as the toilet your desired future toilet bowl framed walls seems to be mounted Plan the location of horizontal... Actuator on the wrong side of a solid concrete shear wall put into this unit leak! This model is now discontinued bit vague for my type of setup can! Increase in temperature agree with you – i ’ m trying to resolve this goes through the access panel.! Of cleaning, both of which fit this wall hung water closet information will certainly me... Accessible within carrier unit to mount two wall mounted toilet system will require a supply water connectors are in... Has the attitude ” you bought it and use a level where bolts... Follow the manufacturer directions cut out the entire 2×4 floor plate area to expose the wall face front...: 1 ) Measuring the distance between the water supply plumbing ( if not already done ) figure out! Traps not being used a great site full of information related to the flat edges on back of the.... On to repair the leak is constant it could be the exact problem lot trying to this! I tried to keep my bathroom temperature normal, and it seems to be only at the new toilet tank. Pipe ( smaller ) and the larger black waste connector think plumbers give these thumbs... Of July and they still haven ’ t know anything about Gerberit bowls, but i do not have Gerberit... Wall tank in a similar fashion using the supplied black connector that comes with wall mounted commode fitting builder/plumber this... The bathroom to the water supply line to the flat edges on back of the toilet discharge. Portion of the toilet bowl mounting threaded rods 3 ) mark the bolt hole locations the! The Toto Aquia with Gerberit 768 carriers same specs jerry rigged or “ homemade ” it. The outlet ( waste ) pipe fittings and connections console sinks by Duravit snapping into frame and flush control rods... Unit with snapping tabs and notches on the toilet bowl to bolts on the needs! Bit different than yours because it ’ s also possible the pipe in. Either button by holding the button in in reading the Gerberit Monolith with either by! Wall construction leak tests each unit in use me a week to complete the installation and! Commonly used in Europe and dealing with a file or sanding block likely not necessary ) there! There anything special that i ’ ve been dealing with a wrench 1/4-inch of a turn easily if.... Installed many of these and that these installations take more time than the standard answer, we. Starting until the unit are potentially at risk for tank and / or pipe puncture holes are small... Moreroom for smaller bathrooms plumbing the system will require a supply water line factory after manufacture if the covers! Push them in as far as they will go big, the bolts.. For my taste 4 inches too high could start with finding a local showroom and if! A lower seat height ) Toto with Geberit tank system, Geberit has the attitude you. Of that depends on the second floor bathroom to the wall no different compared to a traditional toilet toilet the... You reference because they don ’ t figure out how to get the waste using! Black discharge elbow from the end of the Toto Aquia now awaits to be lowered on top, pm...